Backflow, air gaps, vacuum breakers. If you've spent any time managing a food establishment, you've likely come across these terms. And for good reason.


Backflow in a restaurant or commercial kitchen isn't just a plumbing headache. It's a food safety violation waiting to happen. Contaminated water can sneak back into clean lines through unprotected dishwashers, ice machines, or even mop sinks, risking customer health and triggering failed inspections.


In this guide, we'll walk through how to prevent backflow in food establishments, what devices are required, and how to stay ahead of problems before they cost you. If you're unsure which methods apply to your setup (or why prevention is non-negotiable), you're in the right place.


Why Backflow Prevention Matters in Commercial Kitchens


Backflow happens when water flows in the wrong direction, pulling dirty or contaminated water into clean plumbing lines. In a food establishment, that can lead to serious consequences.


Here's why backflow prevention should always be on your radar:

  • It protects your water supply. If water from a mop sink, dishwasher, or dirty drain flows backward into a potable water line, anything it touches can become unsafe.

  • It keeps your kitchen compliant. Health departments often check for proper backflow prevention during inspections. Missing or faulty devices can lead to violations, fines, or shutdowns.

  • It prevents foodborne illness. Backflow can contaminate surfaces, dishes, prep areas, and even the water used in food or drink preparation.

  • It's your responsibility. Business owners, operators, and facility managers are all accountable for keeping plumbing systems in line with local codes.


In short, if your kitchen uses water (and it does), you need backflow protection at every critical connection.


What Is the Only 100% Effective Method for Preventing Backflow?

The only fully foolproof way to prevent backflow is by using an air gap. It's simple, inexpensive, and doesn't rely on moving parts.


What is an air gap?

An air gap is the vertical space between the water outlet and the flood level of a fixture. It ensures that if water backs up, it won't reach the clean supply because gravity keeps the two separate.


Where air gaps are used in kitchens:

  • Between a faucet and the sink basin

  • On dishwashing machines (between drain lines and floor sinks)

  • Where water lines enter ice machines or food prep sinks


Why air gaps work:

  • There's no physical connection between dirty water and clean supply

  • There's no risk of failure due to pressure changes or equipment wear

  • It meets plumbing code requirements for "high-hazard" scenarios


Common Backflow Prevention Devices You'll Need


Here's the thing, though: not every piece of equipment in your kitchen can be protected with an air gap. Many require mechanical backflow preventers, devices designed to stop contaminated water from reversing direction and entering clean lines.


Here are the most common types used in food establishments:


1. Atmospheric Vacuum Breaker (AVB)

  • Protects against back-siphonage, not backpressure

  • Installed downstream of the last shutoff valve

  • Must be mounted vertically and kept above the highest point of water use

  • Often used on hose bibs, mop sinks, or utility sinks


2. Pressure Vacuum Breaker (PVB)

  • Similar to AVB but can be used under continuous pressure

  • Must be installed at least 12 inches above the highest downstream outlet

  • Common in irrigation systems and outdoor water lines


3. Double Check Valve Assembly (DCV)

  • Prevents both backpressure and back-siphonage

  • Contains two independently acting check valves

  • Suitable for low- to medium-hazard situations (e.g., certain beverage systems)


4. Reduced Pressure Zone Assembly (RPZ)

  • The most robust option, used for high-risk systems

  • Has two check valves with a relief valve in between

  • Required when there's a high risk of pollutants (chemicals, cleaners, or waste)

  • Required in San Diego for commercial and industrial meters 1.5” or larger


All backflow devices must be:


Pro tip: If your device fails or isn't tested on time, you risk fines or even water service shut-off.


Where Backflow Prevention Is Required in a Food Establishment


Certain areas of a kitchen are more prone to contamination than others. These are the most common spots where backflow prevention is mandatory:


1. Ice Machines

  • These connect directly to potable water lines

  • A failed valve can allow dirty drain water to back up into clean ice trays

  • Must have an air gap or a certified backflow prevention assembly


2. Mop Sinks and Janitor Closets

  • High-risk due to cleaning chemicals, dirty water, and hose connections

  • Hoses left submerged or placed in buckets can create a direct cross-connection

  • Require vacuum breakers and proper hose bibbs


3. Carbonated Beverage Machines

  • These use CO₂, which can cause carbonic acid buildup in water lines

  • Require special dual check valves approved for carbonated beverage equipment


4. Dishwashers and 3-Compartment Sinks

  • Can siphon dirty water back into clean lines during drain cycles

  • Must have air gaps between drain lines and floor sinks

  • May also require vacuum breakers on sprayers or rinse arms


5. Outdoor Hose Bibs and Faucets

  • Easily overlooked but often used with attachments or submersed hoses

  • Must have hose bibb vacuum breakers or backflow preventers


6. Any System Connected to Chemicals or Alternate Water Sources

  • Examples include chemical feed equipment, fire suppression systems, and auxiliary water tanks

  • These systems are always high-risk and require RPZ assemblies


How Do You Prevent Backflow from Cross-Connections?


Cross-connections are one of the easiest ways for contaminated water to sneak into your clean lines. They form when plumbing setups allow two different water types (clean and dirty) to come too close together.


To prevent issues with cross-connections:

  • Use approved air gaps or valves anytime water is discharged into a drain or basin.

  • Keep hose ends and spray nozzles above the flood level of any sink or bucket.

  • Install backflow assemblies wherever chemicals, cleaning agents, or alternative water sources are used.

  • Never attach a hose to a faucet without a hose bibb vacuum breaker.

  • If you have carbonation systems, make sure a dual check valve rated for CO₂ is in place.


If you're unsure how your system is set up (or if cross-connections are already creating risk), our licensed team at San Diego Backflow Testing can evaluate your kitchen layout and install the right solutions to stop the problem at the source.


How Often Should Backflow Devices Be Tested and Maintained?


Backflow devices need more than a one-time install. To stay compliant and functional, they must be inspected regularly and tested at least once a year.


Here's what a proper maintenance routine includes:


San Diego's regulations require all commercial and multi-family properties with 1.5” or larger meters to follow these testing standards. 


We make it easy. At San Diego Backflow Testing, we'll test your system, complete the paperwork, and remind you when your next test is due. 


How Can Staff Help Keep Backflow From Happening?


Even with all the right devices in place, staff behavior plays a big role in keeping your water safe. Small actions (like how a hose is used or where a sprayer is stored) can create unexpected backflow risks.


Train your team to:

  • Never submerge hoses or sprayers into mop buckets or sinks

  • Avoid leaving pressurized lines unattended or unsecured

  • Know the location and purpose of backflow devices on-site

  • Report any leaks, damaged valves, or missing test tags right away

  • Follow posted signs near sinks or utility areas that indicate backflow risk


Protect Your Kitchen With Certified Backflow Services


Backflow risks can't be ignored, especially in commercial kitchens where food safety, health inspections, and customer trust are all on the line. If you're unsure how to prevent backflow in food establishment plumbing systems, or if your devices haven't been tested recently, it's time to take action.


At San Diego Backflow Testing, we specialize in:


With over 26 years of experience, our team ensures you stay compliant, protected, and worry-free. We'll handle the paperwork, reminders, and everything in between, so you can focus on running your kitchen.


Call 877-363-8378 or send your test form today. Let's keep your water safe, your team protected, and your doors open.




 
 
 